Vacuum Matrix-Assisted Ionization Source Offering Simplicity, Sensitivity, and Exceptional Robustness in Mass Spectrometry
Author(s) -
Sarah Trimpin,
M. Pophristić,
Adetoun AdenijiAdele,
John W. Tomsho,
Charles N. McEwen
Publication year - 2018
Publication title -
analytical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.117
H-Index - 332
eISSN - 1520-6882
pISSN - 0003-2700
DOI - 10.1021/acs.analchem.8b03378
Subject(s) - chemistry , mass spectrometry , ion source , ambient ionization , ionization , analytical chemistry (journal) , reflectron , maldi imaging , analyte , mass spectrum , matrix assisted laser desorption electrospray ionization , orbitrap , matrix (chemical analysis) , ion suppression in liquid chromatography–mass spectrometry , ion , chemical ionization , time of flight mass spectrometry , matrix assisted laser desorption/ionization , thermal ionization mass spectrometry , chromatography , desorption , tandem mass spectrometry , organic chemistry , adsorption
Vacuum matrix-assisted ionization (vMAI) uses select matrix compounds which when exposed to the vacuum of a mass spectrometer produce gas-phase ions from associated volatile or nonvolatile analyte without external energy input. Here, a vMAI source was constructed to replace the commercial inlet of a Thermo Orbitrap mass spectrometer. This allowed for rapid introduction of the matrix/analyte sample by a probe, contrary to vacuum matrix-assisted laser desorption/ionization (MALDI) sources. The matrix/analyte sample is inserted into a region of the "S-lens" entrance, where the spontaneously formed ions can be effectively transferred to the mass analyzer. This specifically designed ion source requires no laser, high voltage, heat, or nebulizing gases. A low voltage is used to transmit the ions through the commercial "S-lens" assembly and airflow can be used to modulate the ionization event. A few picograms of the drug erythromycin, assisted by the 3-nitrobenzonitrile vMAI matrix, is sufficient to produce mass spectra for over 1 min with the MH + ion as the base peak in each mass spectrum. There is minimal carryover when loading high concentration samples and complex mixtures, contrary to direct infusion electrospray ionization, providing the probe is thoroughly cleaned between each new sample acquisition. Analyses of biological fluids, bacterial extracts, tissue, and high concentration samples have so far shown no indication of inlet or instrument contamination with these samples. The typical ultrahigh resolution and mass accuracy of the mass spectrometer are achieved, and a path forward to potential high throughput acquisitions demonstrated. It is expected that robustness can be introduced to any mass spectrometer through implementation of such a simple source.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom