Simple, Robust, and Plasticizer-Free Iodide-Selective Sensor Based on Copolymerized Triazole-Based Ionic Liquid
Author(s) -
Lukasz Mendecki,
Xiaorui Chen,
Nicole Callan,
David F. Thompson,
Benjamin Schazmann,
Sergio Granados-Fócil,
Aleksandar Radu
Publication year - 2016
Publication title -
analytical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.117
H-Index - 332
eISSN - 1520-6882
pISSN - 0003-2700
DOI - 10.1021/acs.analchem.5b04461
Subject(s) - chemistry , iodide , membrane , potentiometric titration , counterion , ion selective electrode , ionic liquid , polymer chemistry , copolymer , click chemistry , methacrylate , inorganic chemistry , combinatorial chemistry , selectivity , polymer , organic chemistry , ion , catalysis , biochemistry
Novel solid-contact iodide-selective electrodes based on covalently attached 1,2,3 triazole ionic liquid (IL) were prepared and investigated in this study. Triazole-based IL moieties were synthesized using click chemistry and were further copolymerized with lauryl methacrylate via a simple one-step free radical polymerization to produce a "self-plasticized" copolymer. The mechanical properties of the copolymer are suitable for the fabrication of plasticizer-free ion-selective membrane electrodes. We demonstrate that covalently attached IL moieties provide adequate functionality to the ion-selective membrane, thus achieving a very simple, one-component sensing membrane. We also demonstrate that the presence of iodide as the counterion in the triazole moiety has direct influence on the membrane's functionality. Potentiometric experiments revealed that each electrode displays high selectivity toward iodide anions over a number of inorganic anions. Moreover, the inherent presence of the iodide in the membrane reduces the need for conditioning. The nonconditioned electrodes show strikingly similar response characteristics compared to the conditioned ones. The electrodes exhibited a near Nernstian behavior with a slope of -56.1 mV per decade across a large concentration range with lower detection limits found at approximately 6.3 × 10(-8) M or 8 ppb. These all-solid-state sensors were utilized for the selective potentiometric determination of iodide ions in artificial urine samples in the nanomolar concentration range.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom