On the use of AAA and AcurosXB algorithms for three different stereotactic ablative body radiotherapy (SABR) techniques: Volumetric modulated arc therapy (VMAT), intensity modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3D-CRT)
Author(s) -
Abdulrahman Tajaldeen,
R Prabhakar,
Sami G. AlGhamdi,
Moshi Geso
Publication year - 2019
Publication title -
reports of practical oncology and radiotherapy
Language(s) - English
Resource type - Journals
eISSN - 2083-4640
pISSN - 1507-1367
DOI - 10.1016/j.rpor.2019.02.008
Subject(s) - sabr volatility model , radiation therapy , nuclear medicine , medicine , imaging phantom , ablative case , algorithm , radiology , mathematics , volatility (finance) , stochastic volatility , econometrics
The purpose of this study was to investigate the dosimetric characteristics of three stereotactic ablative body radiotherapy (SABR) techniques using the anisotropic analytical algorithm (AAA) and Acuros XB algorithm. The SABR techniques include coplanar volumetric modulated arc therapy (C-VMAT), non-coplanar intensity modulated radiation therapy (NC-IMRT) and non-coplanar three-dimensional conformal radiotherapy (NC-3D CRT).