Tent-shape technique: another procedure to repair P2 of posterior leaflet of mitral valve
Author(s) -
Samer Kassem,
Ghassan A. Moasis,
Paolo Biglioli
Publication year - 2010
Publication title -
european journal of cardio-thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.303
H-Index - 133
eISSN - 1873-734X
pISSN - 1010-7940
DOI - 10.1016/j.ejcts.2010.10.013
Subject(s) - chord (peer to peer) , anatomy , mitral valve , medicine , cardiology , computer science , distributed computing
In this report, we describe a new procedure to repair the prolapsing high mid-scallop of the mitral valve (MV) posterior leaflet (P2) with detailed consideration of the anatomy and physiology of the MV. A new artificial chord is implanted in the body of the P2 at the same height of non-prolapsing P1 and P3, and the remaining part of the prolapsing P2 is anchored to the artificial chord taking the shape of a tent.