A simple modification of Ciaglia Blue Rhino technique for tracheostomy: using a guidewire dilating forceps for initial dilation
Author(s) -
ChauChyun Sheu,
JongRung Tsai,
JenYu Hung,
MengHsuan Cheng,
InnWen Chong,
JhiJhu Hwang,
MingShyan Huang
Publication year - 2006
Publication title -
european journal of cardio-thoracic surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.303
H-Index - 133
eISSN - 1873-734X
pISSN - 1010-7940
DOI - 10.1016/j.ejcts.2006.10.006
Subject(s) - medicine , forceps , surgery , percutaneous , dilation (metric space) , mathematics , combinatorics
The potential difficulty in doing initial dilation in the percutaneous dilational tracheostomy (PDT) with the Ciaglia Blue Rhino (CBR) technique has been reported by others and encountered in our clinical practice. To resolve this problem, we developed a modified CBR technique by using a guidewire dilating forceps (GWDF) to facilitate initial dilation. The present before-and-after comparison study aimed to evaluate the clinical benefits of this modified CBR technique.