Moisture damage with magnesium oxide boards in Danish facade structures
Author(s) -
Carsten Rode,
Tommy Bunch-Nielsen,
Kurt Kielsgaard Hansen,
Bent Grelk
Publication year - 2017
Publication title -
energy procedia
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.474
H-Index - 81
ISSN - 1876-6102
DOI - 10.1016/j.egypro.2017.10.025
Subject(s) - moisture , facade , magnesium , oxide , humidity , materials science , composite material , environmental science , metallurgy , structural engineering , engineering , meteorology , physics
Magnesium oxide boards have been widely used on facades in Denmark during 2010-2015. However, the magnesium salts absorb humidity from the ambient, and they begin to leak salty water, which is highly corrosive, and leads to moisture and mould problems in wooden members of the structures. MgO-boards were not tested for their hygrothermal function before being used on exterior wall structures, which has had detrimental consequences, such as an expected cost of repair of around 2 billion DKK. Properties for moisture transport and retention properties have been determined and will be shown together with some examples of damaged structures.