Open-Wedge High Tibial Osteotomy Using a Protective Cutting System: Technical Advancement for the Accuracy of the Osteotomy and Avoiding Intraoperative Complications
Author(s) -
Yong Seuk Lee,
Myung Chul Lee,
Seo Goo Kang,
Ashraf Elazab,
Won Seok Oh
Publication year - 2016
Publication title -
arthroscopy techniques
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.66
H-Index - 31
ISSN - 2212-6287
DOI - 10.1016/j.eats.2015.08.016
Subject(s) - medicine , neurovascular bundle , high tibial osteotomy , osteotomy , surgery , tibial plateau fracture , wedge (geometry) , osteoarthritis , internal fixation , physics , alternative medicine , pathology , optics
Open-wedge high tibial osteotomy for medial unicompartmental arthritis of the knee joint is a successful treatment option but is associated with potential intraoperative complications such as tibial plateau fracture, dislocation of the osteotomy hinge, under- or over-correction of the posterior slope, and neurovascular injury. Therefore we devised a protective cutting system and describe our method for the prevention of these complications. The potential advantages of this system are protection of the posterior neurovascular structures using a curved protector, bone cutting along the natural tibial slope using a superior surface aligning with the natural tibial slope, and complete 1-plane sawing of the posterior wall before the lateral hinge.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom