A Technique of Superficial Medial Collateral Ligament Reconstruction Using an Adjustable-Loop Suspensory Fixation Device
Author(s) -
Shaneel Deo,
Alan Getgood
Publication year - 2015
Publication title -
arthroscopy techniques
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.66
H-Index - 31
ISSN - 2212-6287
DOI - 10.1016/j.eats.2015.02.005
Subject(s) - medicine , fixation (population genetics) , soft tissue , surgery , medial collateral ligament , suspensory ligament , range of motion , ligament , population , environmental health
This report describes superficial medial collateral ligament reconstruction of the knee using a novel method of graft fixation with the ACL Tightrope RT (Arthrex, Naples, FL). After tibial fixation with either a standard interference screw or staple, femoral fixation of the semitendinosus tendon is performed with the adjustable-loop suspensory fixation device, which allows for both initial graft tensioning and re-tensioning after cyclical knee range of motion. This provides the ability for the graft to accommodate for resultant soft-tissue creep and stress relaxation, thereby allowing for optimal soft-tissue tension and reduction in laxity at the end of the procedure.