Ablation of common atrial flutter: comparison of irrigated tip versus 8 mm tip catheters
Author(s) -
Serge Bovéda,
Michel Galinier,
Marc Delay,
JeanLuc Puel,
JeanMarie Fauvel,
Philippe Lagrange,
A. Lagrange,
Thomas Arentz,
P Defaye,
P Blanc
Publication year - 2001
Publication title -
ep europace
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.119
H-Index - 102
eISSN - 1532-2092
pISSN - 1099-5129
DOI - 10.1016/eupace/2.supplement_1.a57
Subject(s) - medicine , ablation , atrial flutter , cardiology , catheter ablation
Methods : This multicenter prospective study (jan-oct 99) included 145 consecutive patients with AFI, (81% male, 63 years) treated with 8 mm tip catheters (group I, n=81) or IT (group II, n=64). Applications were done during 60 sec with temperature controlled mode : 55-600C/up to 50-100W in Gp I or 50°C/up to 50W in Gp II (17 cc/min external or 36 cc/min internal saline flow rate). Time of procedure included 30 rain wait.