z-logo
open-access-imgOpen Access
Acromioclavicular and coracoclavicular ligamentous insertion distances depend on the scapular tilt and decrease with anterior direction of the inferior scapula angle
Author(s) -
Sußiek Julia,
Wermers Jens,
Raschke Michael J.,
Herbst Elmar,
Dyrna Felix,
Riesenbeck Oliver,
Katthagen J. Christoph
Publication year - 2023
Publication title -
knee surgery, sports traumatology, arthroscopy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.806
H-Index - 125
eISSN - 1433-7347
pISSN - 0942-2056
DOI - 10.1007/s00167-022-07126-9
Subject(s) - scapula , coracoclavicular ligament , tilt (camera) , acromioclavicular joint , clavicle , anatomy , medicine , geology , orthodontics , geometry , mathematics
Purpose A variety of reconstruction techniques exist for the operative treatment of a ruptured acromioclavicular and coracoclavicular ligamentous complex. However, the complication rate remains high; between 5 and 89%.The intraoperative distance between the clavicle, acromion and coracoid is important for the refixation quality. In this study, the influence of scapular deflection on coracoclavicular and acromioclavicular distances was analysed. Methods The ligamentous insertions of 24 fresh‐frozen human scapulae were exposed. The coracoclavicular and acromioclavicular ligaments were referenced and captured in a rigid body system using a three‐dimensional (3D) measurement arm. The inferior angle of the scapula was manually pulled into maximum anterior and posterior deflection, simulating a patient positioning with or without dorsal scapular support, respectively. Based on the rigid body system, the distances between the ligamentous insertions were calculated. Statistical evaluation was performed by setting the distances in anterior deflection to 100% and considering the other distances relative to this position. Results The scapular deflection had a considerable impact on the distance between the ligamentous insertions. Concerning the conoid ligament, the mean distance was almost doubled when the inferior angle pointed posteriorly compared to anterior deflection (195.3 vs 100.0%; p  = 0.028). The insertion of the acromioclavicular capsule also showed a significant association with the direction of deflection (posterior = 116.1% vs. anterior = 100%; p  = 0.008). Conclusion Dorsal support shifting the inferior angle of the scapula anteriorly reduces the distance between the ligamentous insertions. Therefore, a patient position on a shoulder table with posterior support of the scapula is recommended to reliability reduce the acromioclavicular joint.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here