NIRS: So near yet so far (From the brain)
Author(s) -
Suman Subbaraya Kandachar,
Anbarasu Annamalai
Publication year - 2020
Publication title -
annals of cardiac anaesthesia/annals of cardiac anaesthesia
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.42
H-Index - 27
eISSN - 0974-5181
pISSN - 0971-9784
DOI - 10.4103/aca.aca_97_19
Subject(s) - medicine , medline , intensive care medicine , law , political science
Cerebral oximetry is touted as a magic wand to detect cerebral hypoperfusion. Inability to completely exclude extracranial oxygen however is a limitation. Variation in scalp vascularity can magnify the limitations of relatively short emitter-detector distances. The combination of brain ischemia and cutaneous hyperemia, as is the situation during anaphylaxis and anaphylactoid reactions, can be associated with a paradoxical increase in cerebral oximetry values. This could compromise the quality and accuracy of care delivered. We report the association of red man syndrome with exaggerated cerebral oximetry values.