Factors Related to Instrumentation Failure in Titanium Mesh Reconstruction for Thoracic and Lumbar Tumors: Retrospective Analysis of 178 Patients
Author(s) -
Wei-dong Bao,
Qi Jia,
Tao Wang,
Yan Lou,
Dongjie Jiang,
Cheng Yang,
Xianghong Yang,
Quan Huang,
Haifeng Wei,
Jianru Xiao
Publication year - 2021
Publication title -
cancer management and research
Language(s) - English
Resource type - Journals
ISSN - 1179-1322
DOI - 10.2147/cmar.s294616
Subject(s) - medicine , vertebra , lumbar , radiation therapy , thoracic vertebrae , lumbar vertebrae , surgery , univariate analysis , retrospective cohort study , radiology , multivariate analysis
To investigate risk factors for instrumentation failure (IF) in titanium (Ti) mesh reconstruction for thoracic and lumbar tumors.