Pipe-Cleaning Plugged Portacaths: How to Unclog an Implanted Port After Development of a Fibrin Sheath
Author(s) -
Hagaman Sean,
Matteo Jerry,
Kee-Sampson Joanna,
Bashir Saeed,
Le Rebecca T.,
Meyer Travis E.
Publication year - 2020
Publication title -
vascular and endovascular surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.46
H-Index - 45
eISSN - 1938-9116
pISSN - 1538-5744
DOI - 10.1177/1538574419900054
Subject(s) - medicine , fibrin , port (circuit theory) , surgery , venous access , catheter , vascular access , hemodialysis , electrical engineering , engineering , immunology
Industry has long fought the battle to design a vascular catheter that is less thrombogenic. Indwelling catheters provide long-term central venous access, but they develop fibrin sheaths as the vascular system recognizes them as foreign bodies. Peripheral catheters and central catheters can be changed over a guidewire when they form a fibrin sheath or otherwise malfunction. However, totally implantable venous access devices such as a port cannot be easily exchanged over a wire. Therefore, when a port malfunctions, thrombolytics are usually the only option attempted before the port is explanted and a new site is prepared for access. We present a minimally invasive technique demonstrating port salvage that does not require explant.