z-logo
open-access-imgOpen Access
Left Atrial Inexcitability in Children With Congenital Lupus‐Induced Complete Atrioventricular Block
Author(s) -
Abadir Sylvia,
Fournier Anne,
Vobecky Suzanne J.,
Rohlicek Charles V.,
Romeo Philippe,
Khairy Paul
Publication year - 2015
Publication title -
journal of the american heart association
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.494
H-Index - 85
ISSN - 2047-9980
DOI - 10.1161/jaha.115.002676
Subject(s) - medicine , cardiology , atrioventricular block , intracardiac injection , heart block , complication , electrocardiography
Background Congenital atrioventricular block is a well‐established immunologic complication of maternal systemic lupus erythematosus. We sought to further characterize the electrophysiological manifestations of maternal systemic lupus erythematosus on neonatal atria. Methods and Results Cases of isolated congenital atrioventricular block treated at our center over the past 41 years were identified. Data were extracted from clinical charts, pacemaker interrogations, ECGs, echocardiograms, and histopathological reports, when available. Of 31 patients with isolated congenital atrioventricular block, 18 were negative for maternal antibodies and had normal epicardial atrial sensing and pacing thresholds. In contrast, 12 of 13 patients with positive maternal antibodies had epicardial pacemakers, 5 (42%) of whom had left atrial ( LA ) inexcitability and/or atrial conduction delay. In 3 patients, the LA could not be captured despite high‐output pacing. The fourth patient had acutely successful LA appendage and left ventricular lead placement. At early follow‐up, an increased delay between the surface P‐wave and intracardiac atrial depolarization was observed, indicative of atrial conduction delay. The fifth patient exhibited LA lead dysfunction, with atrial under‐sensing and an increased capture threshold, 2 weeks after implantation. Biopsies of LA appendages performed in 2 patients showed no evidence of atrial fibrosis or loss of atrial myocytes. Conclusions Herein, we report previously undescribed yet prevalent electrophysiological ramifications of maternal systemic lupus erythematosus, which extend beyond congenital atrioventricular block to encompass alterations in LA conduction, including LA inexcitability. These manifestations can complicate epicardial pacemaker implantation in newborns. In the absence of histological evidence of extensive atrial fibrosis, immune‐mediated functional impairment of electrical activity is suspected.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here