Premium
Erythritol airpolishing in the non‐surgical treatment of peri‐implantitis: A randomized controlled trial
Author(s) -
Hentenaar Diederik F. M.,
De Waal Yvonne C. M.,
Stewart Roy E.,
Van Winkelhoff Arie Jan,
Meijer Henny J. A.,
Raghoebar Gerry M.
Publication year - 2021
Publication title -
clinical oral implants research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.407
H-Index - 161
eISSN - 1600-0501
pISSN - 0905-7161
DOI - 10.1111/clr.13757
Subject(s) - medicine , peri implantitis , bleeding on probing , dentistry , visual analogue scale , randomized controlled trial , ultrasonic sensor , erythritol , periodontitis , implant , surgery , radiology , chemistry , food science
Abstract Objectives To compare erythritol air polishing with piezoelectric ultrasonic scaling in the non‐surgical treatment of peri‐implantitis. Material and methods Eighty patients ( n = 139 implants) with peri‐implantitis (probing pocket depth (PPD) ≥5 mm, marginal bone loss (MBL) ≥2 mm as compared to bone level at implant placement, bleeding, and/or suppuration on probing (BoP/SoP)) were randomly allocated to air polishing or ultrasonic treatment. The primary outcome was mean BoP (%) at 3 months after therapy (T3). Secondary outcomes were mean SoP (%), plaque score (Plq) (%), PPD (mm), MBL (mm), full mouth periodontal scores (FMPS) (%), levels of 8 classical periodontal pathogens, and treatment pain/discomfort (Visual Analog Scale, VAS). Patients who were considered successful at T3 were additionally assessed at 6, 9, and 12 months. Differences between both groups were analyzed using multilevel statistics. Results Three months after therapy, no significant difference in mean BoP (%) between the air polishing and ultrasonic therapy was found (crude analysis β (95% CI) −0.037 (−0.147; 0.073), p = .380). Neither secondary outcomes SoP (%), Plq (%), PPD (mm), MBL (mm), FMPS (%), and periodontal pathogens showed significant differences. Treatment pain/discomfort was low in both groups (VAS score airpolishing group 2.1 (±1.9), ultrasonic 2.6 (±1.9); p = .222). All successfully treated patients at T3 (18.4%) were still considered successful at 12‐month follow‐up. Conclusions Erythritol air polishing seems as effective as piezoelectric ultrasonic scaling in the non‐surgical treatment of peri‐implantitis, in terms of clinical, radiographical, and microbiological parameters. However, neither of the proposed therapies effectively resolved peri‐implantitis. Hence, the majority of patients required further surgical treatment.