Study on Modification of Inside Environment in Windowless Weaning Piglet House
Author(s) -
SeungJoo Lee,
Winson M. Gutierrez,
Bong-Sik Kim,
Jin-Young Han,
Dongil Chang,
Hong-Hee Chang
Publication year - 2008
Publication title -
korean journal of environmental agriculture
Language(s) - English
Resource type - Journals
eISSN - 2233-4173
pISSN - 1225-3537
DOI - 10.5338/kjea.2008.27.2.150
Subject(s) - weaning , passive house , zoology , architectural engineering , materials science , engineering , biology , electrical engineering , efficient energy use
This study was carried out to determinate the location and the number of air inlet and outlet, optimum air inlet velocity for effective ventilation in windowless weaning piglet house( m) by CFD(Computation Fluid Dynamics) simulation. The weaning piglet house for this experiment was consisted of 11 air inlets and 9 outlets, modified and simulated using CFD code, FLUENT. The simulation result for the original weaning piglet house, which was not modified, showed ununiform ventilation for each room. Therefore, for uniform ventilation, 4 air inlets and 1 outlet were completely closed, and 2 air outlets were partially closed. The simulation result for the modified weaning piglet house showed uniform ventilation for each room and the optimum air inlet velocity of 0.5 .