z-logo
open-access-imgOpen Access
Development of Visually Improved Loop Mediated Isothermal Amplification for the Diagnosis of Plasmodium vivax Malaria in a Tertiary Hospital in Chandigarh, North India
Author(s) -
Hargobinder Kaur,
Rakesh Sehgal,
Devendra Bansal,
Ali A. Sultan,
Ashish Bhalla,
Sunit Singhi
Publication year - 2018
Publication title -
american journal of tropical medicine and hygiene
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.015
H-Index - 151
eISSN - 1476-1645
pISSN - 0002-9637
DOI - 10.4269/ajtmh.17-0857
Subject(s) - loop mediated isothermal amplification , plasmodium vivax , malaria , gold standard (test) , vivax malaria , polymerase chain reaction , rapid diagnostic test , multiplex , nested polymerase chain reaction , multiplex polymerase chain reaction , biology , virology , medicine , immunology , gene , bioinformatics , genetics , plasmodium falciparum , dna
More than 80% of the global burden of the Plasmodium vivax is contributed by mainly three countries (India, Indonesia, and Pakistan). Reports from last decades have highlighted the occurrence of severe P. vivax malaria which was earlier considered to be benign. The recent trends of increasing P. vivax -associated morbidity and mortality emphasizes the need for early and accurate diagnosis of P. vivax malaria for the timely management of patients. Microscopy is considered a gold standard but needs experienced laboratory technologists. Over the last few years, Polymerase chain reaction (PCR) is being used as a highly sensitive and specific test but it requires expensive equipment which limits its use in the field. Therefore, in the present study, utility of visually improved loop-mediated isothermal amplification (LAMP) for the detection of P. vivax was evaluated targeting 18SrRNA gene in 145 microscopically confirmed P. vivax and 20 P. vivax negative patients. Sensitivity and specificity of LAMP was assessed with respect to microscopy and multiplex nested PCR (nPCR). Results of the LAMP assay was also correlated with rapid diagnostic test, multiplex nPCR and real-time PCR results. Overall, sensitivity and specificity of P. vivax -specific LAMP compared with microscopy were found to be 100% and 85%, respectively. Furthermore, detection limit for LAMP was found to be 0.8 copies/μL and it was also able to detect three complicated cases of P. vivax which were missed by microscopy. This study showed a LAMP assay to be a rapid and very sensitive method for the early diagnosis of both complicated and uncomplicated P. vivax malaria.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom