Study on value of Extended-Focused Abdominal Scan For Trauma (e-FAST) performed by non-radiologist emergency care doctors in Management of Trauma at Emergency Trauma Centre, Teaching Hospital, Karapitiya,Galle, Sri Lanka
Author(s) -
R. W. Seneviratne,
M Ajith Kumara,
J. P. M. Kumarasinghe,
R Abewickrama,
Kithsiri Jayasekara,
A Abewickrama,
PV De Silva
Publication year - 2015
Publication title -
anuradhapura medical journal
Language(s) - English
Resource type - Journals
eISSN - 2345-9719
pISSN - 2279-3771
DOI - 10.4038/amj.v9i1.7539
Subject(s) - medicine , promotion (chess) , health care , publication , public health , medical emergency , nursing , political science , politics , law
Background\udThis study was designed to evaluate the accuracy and usefulness of ultrasound in the hands of emergency physicians and medical officers who are non-radiologistsin assessing Trauma patients at Emergency Trauma Centre(ETC) at Teaching Hospital, Karapitiya, Galle, Sri Lanka\udMethodology\udWe performed an observational study on Trauma patients admitted to Emergency Department at Teaching Hospital, Karapitiya from 1.12.2014 to 31.12.2014 who fulfilled indications for e-FAST using a specially designed performa. Accuracy of eFAST was tested by comparing the original with subsequent imaging, clinical decision by surgeons, findings at surgery or more than one of the above.\udResults\ud69 patients fulfilled the entry criteria.Nineteen of the scans were performed by consultants while rest was done by senior medical officers. All of them were trained in eFAST. Of the 20 scans which were positive there were four pneumothoraxes and one haemothorax. 15 scans which were positive for intraperitoneal free fluid were later. Out of 49 Patients who had negative scans 47 did not require surgery or any interventions. Other two required laparotomy later. Sensitivity and specificity ofeFast was 90.4% and 97.9% respectively. Positive predictive value was 95.0% while Negative predictive value was at 95.9% .\udConclusions\udeFAST is a rapidand reliable alternative in detecting free intra-abdominal fluid as well as pneumotorax and haemothorax. It is a safe decision making tool which can be used with confidence and accuracy after brief training and experience by non radiologists which will reduce morbidity and mortality in trauma patients of Sri Lanka
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom