Testing Results of Magnetostrictive Ultrasonic Sensor Cables for Signal Loss
Author(s) -
JT Evans
Publication year - 2005
Language(s) - English
Resource type - Reports
DOI - 10.2172/883695
Subject(s) - magnetostriction , signal (programming language) , transducer , ultrasonic sensor , acoustics , electromagnetic acoustic transducer , ultrasonic testing , signal generator , materials science , electrical engineering , engineering , computer science , voltage , physics , magnetic field , quantum mechanics , programming language
The purpose of this test was to determine the signal strength and resolution losses of a magnetostrictive ultrasonic system with an extended signal cable. The cable of interest carries electrical signals between the pulse generator/receiver and the magnetostrictive transducer. It was desired to determine the loss introduced by different lengths of the signal cable (6', 100', and 200')