Development of Gear-Type Vane Dampers to Replace Link-Type Vane Dampers in Marine FD Fans
Author(s) -
Nam-Soo Hur,
Sung-Cheol Jang,
Kyung-Jun Lee
Publication year - 2016
Publication title -
journal of the korean society of industry convergence
Language(s) - English
Resource type - Journals
ISSN - 1226-833X
DOI - 10.21289/ksic.2016.19.4.216
Subject(s) - damper , backlash , structural engineering , engineering , actuator , torque , automotive engineering , control theory (sociology) , mechanical engineering , computer science , control (management) , physics , electrical engineering , thermodynamics , artificial intelligence
Thus, this study aimed to develop a gear-type vane damper in order to replace the link-type vane damper. To achieve this goal, the torque generated in a gear-type vane damper was analyzed, and a structural analysis was conducted. In addition, the fluid flow was analyzed according to the changes in the vane’s angle, and experimental tests such as a dry-heat test and cold test were conducted considering the operating conditions of the vessels. Moreover, an appropriate actuator was selected for the developed gear-type vane damper, and studies on the reduction in the backlash due to the facing-pressure adjustment length and flow rate and leakage test due to the vane’s angle were conducted.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom