Effect of Dried Blood Spot Quality on Newborn Screening Analyte Concentrations and Recommendations for Minimum Acceptance Criteria for Sample Analysis
Author(s) -
Roanna George,
Stuart J. Moat
Publication year - 2015
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1373/clinchem.2015.247668
Subject(s) - analyte , dried blood spot , dried blood , chromatography , sample (material) , medicine , chemistry
BACKGROUND The analysis of dried blood spots has been used routinely for newborn screening since the early 1970s, and the number of disorders screened has expanded substantially in recent years. However, there is a lack of evidence regarding minimum blood spot quality acceptance criteria for sample analysis. METHODS Blood pools were spiked with phenylalanine, tyrosine, leucine, methionine, octanoylcarnitine, decanoylcarnitine, isovalerylcarnitine, glutarylcarnitine, thyroid-stimulating hormone, and immunoreactive trypsinogen to concentrations at the analytical cutoffs used in UK screening protocols. We evaluated the effect of sample volume applied to the card (10, 20, 50, 75, and 100 μL), punch location (central vs peripheral), and sample quality (double layering, applying blood to both sides of the filter paper, multispotting, applying insufficient sample, and compressing the sample after application). RESULTS Compression of blood spots produced significantly lower results (14%–44%) for all analytes measured (P < 0.001). Smaller blood spots produced significantly lower results (15%–24% for 10-μL vs 50-μL sample size) for all analytes at all concentrations measured (P < 0.001). Results obtained from peripheral punches were higher than those from a central punch, although this did not reach statistical significance for all analytes. Insufficient and multispotted samples demonstrated heterogeneous results. CONCLUSIONS All blood spots containing ≤20 μL (blood spot diameter <8 mm), those in which blood has not fully penetrated the filter paper, and all samples with evidence of compression should be rejected, since there is a risk of producing false-negative results.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom