Partial Discharge Measurements on 110kV Current Transformers. Case Study. Results
Author(s) -
Cristian DAN,
R. Morar
Publication year - 2017
Publication title -
destech transactions on engineering and technology research
Language(s) - English
Resource type - Journals
ISSN - 2475-885X
DOI - 10.12783/dtetr/iceea2016/6637
Subject(s) - partial discharge , transformer , amplitude , current transformer , data acquisition , electrical engineering , system of measurement , engineering , computer science , electronic engineering , acoustics , voltage , physics , optics , operating system , astronomy
The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV instrument transformers located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharge, product of Mtronix Precision Measuring Instruments. MPD600 consists of three acquisition units (to separate, this way, the DP signal from electromagnetic disturbances, based on the three Phase Amplitude Relation Diagram – 3 PARD), an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Measurements, with the ability to be calibrated, do render: a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 and IEC 61869-5: 2011; the possibility to determine the nature of the fault by identifying defective winding. Considering the results, the 110kV instrument transformer was directed to the repair shop and had the fault identified. The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV instrument transformers located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharge, product of Mtronix Precision Measuring Instruments. MPD600 consists of three acquisition units (to separate, this way, the DP signal from electromagnetic disturbances, based on the three Phase Amplitude Relation Diagram – 3 PARD), an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Measurements, with the ability to be calibrated, do render: a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 and IEC 61869-5: 2011; the possibility to determine the nature of the fault by identifying defective winding. Considering the results, the 110kV instrument transformer was directed to the repair shop and had the fault identified.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom