z-logo
open-access-imgOpen Access
MON-111 Plasma Insulin Measured with a Sensitive Immunoassay May Establish the Diagnosis of Congenital Hyperinsulinism Without Further Testing
Author(s) -
Julie Siersbæk,
Annette Rønholt Larsen,
Mads Nybo,
Henrik Thybo Christesen
Publication year - 2020
Publication title -
journal of the endocrine society
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.046
H-Index - 20
ISSN - 2472-1972
DOI - 10.1210/jendso/bvaa046.1738
Subject(s) - congenital hyperinsulinism , medicine , insulin , immunoassay , receiver operating characteristic , endocrinology , gold standard (test) , hyperinsulinism , hypoglycemia , detection limit , gastroenterology , chemistry , chromatography , insulin resistance , immunology , antibody
Background: The diagnosis of congenital hyperinsulinism (CHI) is often hampered by a plasma insulin (p-insulin) detection limit of 2-3 mU/L (14-21 pmol/L) by RIA methods. Objective: To evaluate the diagnostic performance of a sensitive immunoassay for p-insulin and to find the optimal p-insulin cut-off for CHI versus other conditions with hypoglycaemia. Design: Single centre retrospective cohort study. Methods: Diagnostic tests with no medication, no i.v. glucose and under fasting conditions were performed in children with a clinical diagnosis of CHI. P-insulin concentrations determined at simultaneous p-glucose concentrations at least <3.2 mmol/L (57.5 mg/dL) were included in the analysis (n=61). The diagnosis of CHI was either clinical (n=61) or by gold standard criteria: hypoketotic hypoglycaemia plus disease-causing genetic mutations and/or diffuse, focal or atypical pancreatic histopathology (n=57). Samples from 15 children with idiopathic ketotic hypoglycaemia (IKH, diagnosis by exclusion, p-ketones >1.5 mmol/L during hypoglycaemia) were used as controls. P-insulin was measured by the high-sensitive assay (Cobas e411 immunoassay analyzer); lower detection limit 1.4 pmol/L (0.2 mU/L); normal range 18-173 pmol/L (2.57-24.7 mU/L). Concentrations <18 pmol/L were considered suppressed; ≥18 pmol/L un-suppressed. Receiver operating characteristics (ROC) curves with determination of area under the curve (AUC) values were performed for the diagnostic performance of p-insulin in the diagnosis of CHI. Results: In the 61 samples from CHI patients, the median (range) p-insulin was un-suppressed in all diagnostic samples [90; 20-758 pmol/L (12.9; 2.9-109.1 mU/L)], while p-insulin was suppressed in all 15 samples from IKH patients [1.5; 1.5-9 pmol/L (0.21; 0.21-1.3 mU/L)]. The ROC AUC was 1.0 (95%CI. 1.0-1.0) for the diagnosis of CHI defined both by the clinic and by gold standard. The optimal p-insulin cut-off was 14.5 pmol/L (2.1 mU/L) or 12.5 pmol/L (1.8 mU/L), for CHI patients by use of a simultaneous p-glucose cut-off of <3.2 mmol/L (57.5 mg/dL; n=61), or 3.0 mmol/L (55 mg/dL; n=49), respectively. Conclusions: The sensitive insulin assay performed excellent in diagnosing CHI with a ROC AUC of 1.0. The use of a p-insulin cut-off of 13 pmol/L (1.86 mU/L) during a diagnostic hypoketotic hypoglycaemia test may establish the diagnosis of CHI without further diagnostic testing.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom