A Novel Specific Immunoassay for Plasma Two-Chain Factor VIIa: Investigation of FVIIa Levels in Normal Individuals and in Patients With Acute Coronary Syndromes
Author(s) -
Helen Philippou,
Antonella Adami,
Rajiv Amersey,
Peter Stubbs,
David A. Lane
Publication year - 1997
Publication title -
blood
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 5.515
H-Index - 465
eISSN - 1528-0020
pISSN - 0006-4971
DOI - 10.1182/blood.v89.3.767
Subject(s) - recombinant factor viia , immunoassay , unstable angina , medicine , antibody , tissue factor , coefficient of variation , recombinant dna , myocardial infarction , immunology , chemistry , coagulation , chromatography , biochemistry , gene
We report the development of an enzyme-linked immunosorbent assay (ELISA) that is specific for factor VIIa (FVIIa). This assay uses a neoantigen specific capture antibody directed to the amino acid peptide sequence N terminal to the FVII cleavage activation site. The antibody exhibits approximately 3,000-fold greater reactivity to FVIIa than FVII on a molar basis. Experiments using plasma with added (exogenous) human FVIIa gave quantitative recovery in the ELISA over a range of 0.20 to 3.2 ng/mL of FVIIa. The intra- and inter-assay coefficient of variation (CVs) of the ELISA are 4.5% and 9.8%, respectively. The ELISA shows excellent correlation (r = .99) with a functional assay (using recombinant soluble tissue factor) in detecting FVIIa added to plasma over the range 0.05 to 18.0 ng/mL. However, a major discrepancy exists between the two assays when normal endogenous plasma concentrations of FVIIa are measured. Using normal plasma (n = 14) the functional assay reported 3.10 +/- 0.30 ng/mL (mean +/- SE) whereas only 0.025 +/- 0.010 ng/mL was detected in the same samples by the immunoassay. Patients (n = 43) presenting with acute coronary syndromes (myocardial infarction and unstable angina) exhibited elevations (P < .05) in immunologically detected FVIIa, 0.093 +/- 0.013 ng/mL (mean +/- SE) compared to patient controls (n = 20) contemporaneously admitted with noncardiac chest pain, 0.048 +/- 0.007 ng/mL (mean +/- SE). These elevations in the acute coronary syndromes were accompanied by increased (P < .05) and correlating prothrombin fragment F1 + 2 levels (Spearman correlation coefficient rs = .4, P < .01), demonstrating that thrombin generation is certainly associated with, and may even be caused by, extrinsic pathway activation.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom