Biomechanical Comparison of a First- and a Second-Generation All-Soft Suture Glenoid Anchor
Author(s) -
Erickson John,
Chiarappa Frank,
Haskel Jonathan,
Rice Justin,
Hyatt Adam,
Monica James,
Dhawan Aman
Publication year - 2017
Publication title -
orthopaedic journal of sports medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.329
H-Index - 35
ISSN - 2325-9671
DOI - 10.1177/2325967117717010
Subject(s) - cadaveric spasm , fibrous joint , medicine , displacement (psychology) , ultimate load , soft tissue , ultimate failure , biomechanics , orthodontics , surgery , barbed suture , anatomy , structural engineering , ultimate tensile strength , materials science , composite material , finite element method , engineering , psychology , psychotherapist
Background: All–soft tissue suture anchors provide advantages of decreased removal of bone and decreased glenoid volume occupied compared with traditional tap or screw-in suture anchors. Previous published data have led to biomechanical concerns with the use of first-generation all-soft suture anchors.Purpose/Hypothesis: The purpose of this study was to evaluate the load to 2-mm displacement and ultimate load to failure of a second-generation all-soft suture anchor, compared with a first-generation anchor and a traditional PEEK (polyether ether ketone) anchor. The null hypothesis was that the newer second-generation anchor will demonstrate no difference in loads to 2-mm displacement after cycling compared with first-generation all-soft suture anchors.Study Design: Controlled laboratory study.Methods: Twenty human cadaveric glenoids were utilized to create 97 total suture anchor sites, and 1 of 3 anchors were randomized and placed into each site: (1) first-generation all-soft suture anchor (Juggerknot; Biomet), (2) second-generation all-soft suture anchor (Suturefix; Smith & Nephew), and (3) a control PEEK anchor (Bioraptor; Smith & Nephew). After initial cyclic loading, load to 2 mm of displacement and ultimate load to failure were measured for each anchor.Results: After cyclic loading, the load to 2-mm displacement was significantly less in first-generation anchors compared with controls ( P < .01). However, the load to 2-mm displacement was significantly greater in second-generation anchors compared with controls ( P < .01). There was no difference in ultimate load to failure between the first- and second-generation all-soft suture anchors ( P > .05).Conclusion: The newer generation all-soft suture anchors with a theoretically more rigid construct and deployment configuration demonstrate biomechanical characteristics (specifically, with load to 2-mm displacement after cyclic loading) that are improved over first-generation all-soft suture anchors and similar to a traditional solid tap-in anchor. The configuration of these newer generation all-soft suture anchors appears to mitigate the biomechanical concerns of decreased load to failure with first-generation all–soft tissue suture anchors.Clinical Relevance: The theoretical advantages of all-soft anchors may be particularly valuable in revision surgery or in cases where multiple anchors are being placed into a small anatomic area.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom