Modified fibrinolytic therapy as treatment of mechanical aortic valve thrombosis
Author(s) -
Ala Mustafa,
Todd Thomas,
Robert Murdock,
Samuel Congello
Publication year - 2021
Publication title -
sage open medical case reports
Language(s) - English
Resource type - Journals
ISSN - 2050-313X
DOI - 10.1177/2050313x21999202
Subject(s) - medicine , thrombosis , mechanical valve , fibrinolysis , surgery , fibrinolytic therapy , aortic valve , fibrinolytic agent , regimen , cardiology , antithrombotic
Prosthetic valve thrombosis is a rare phenomenon with limited treatment options. Current management choices include anticoagulation with or without fibrinolysis or surgical valve replacement for appropriate candidates. We report an alternative fibrinolytic and anticoagulation regimen resulting in successful treatment of a patient presenting with mechanical aortic valve thrombosis.