Renal artery injury during inferior vena cava filter removal with endobronchial forceps
Author(s) -
Padula Carlos A,
Lewis Andrew R,
Frey Gregory T,
McKinney J Mark,
Paz-Fumagalli Ricardo,
Ritchie Charles A,
Devcic Zlatko,
Toskich Beau B
Publication year - 2019
Publication title -
jrsm cardiovascular disease
Language(s) - English
Resource type - Journals
ISSN - 2048-0040
DOI - 10.1177/2048004019893513
Subject(s) - medicine , forceps , renal artery , surgery , stent , radiology , inferior vena cava , kidney
Retrieval of tip-embedded inferior vena cava filters using endobronchial forceps is a well-described technique. The tip of dorsally tilted filters may be in proximity to the right renal artery, increasing the risk of arterial injury during retrieval. We present one case that illustrates renal artery injury requiring emergent stent graft repair. The three subsequent cases illustrate techniques that avoid renal artery injury using a femoral and jugular approach with the assistance of an arterial fiducial wire. Renal artery injury is a potential complication during retrieval of filters using endobronchial forceps that can be prevented with careful planning.