Assessment of Airborne Culturable Fungal Load in an Indoor Environment of Dormitory Rooms: The Case of University of Gondar Student’s Dormitory Rooms, Northwest Ethiopia
Author(s) -
Zewudu Andualem,
Yeshambel Ayenew,
Temesel Ababu,
Betelhem Hailu
Publication year - 2020
Publication title -
air soil and water research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.409
H-Index - 12
ISSN - 1178-6221
DOI - 10.1177/1178622120933553
Subject(s) - alternaria , cladosporium , penicillium , indoor air quality , geotrichum , indoor air , toxicology , environmental health , fusarium , environmental science , veterinary medicine , biology , microbiology and biotechnology , food science , medicine , environmental engineering , horticulture
Pollution caused by fungal contamination on building materials contributes to poor indoor air quality. Fungi are known to cause several health-related problems, such as acute toxicity, hypersensitivity, invasive mycoses, and respiratory problems. Thus, this study aimed to determine the load and diversity of airborne culturable fungi in the dormitory rooms. An institution-based cross-sectional study was conducted from March to June 2019 at the University of Gondar students’ dormitory rooms. Statistical analyses were carried out using Stata/SE 14.0. Spearman ranks correlation was used to assess the correlation of fungal load with indoor physical parameters. The median fungal loads were 250 CFU/m3 and 157 CFU/m3 in the morning and afternoon, respectively. Most commonly identified fungal genera/species were Aspergillus, Penicillium, Alternaria, Fusarium, Candida, Trichophyton, Piedraia, Microsporum, Geotrichum, Saccharomyces, Rhodotorula, Rhizopus, Exophiala, Arthroderma, Cladosporium, Gliocladium, and Botrytis. Formaldehyde (r = −0.2859, P = .0031), temperature (r = −0.2153, P = .0274), and CO2 (r = −0.3785, P = .0001) were negatively correlated with airborne indoor fungal load in the morning and CO2 (r = 0.3183, P = .0009) and temperature (r = 0.2046, P = .0363) positively correlated with airborne indoor fungal load in the afternoon. As a conclusion, the airborne fungal load in the dormitory room was intermediate according to the European standard of nonindustrial premises. Substantial action should be taken to reduce the fungal contamination of indoor environments.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom