The Assessment of Peritoneal Function Using a Single Hypertonic Exchange
Author(s) -
Nikolakakis Nik,
Stuart R.,
Timothy C. Rodger,
Goodship H. J.,
Fletcher Kate,
Ashcroft Rosalind,
Wilkinson Robert,
Ward Michael K.
Publication year - 1985
Publication title -
peritoneal dialysis international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.79
H-Index - 83
eISSN - 1718-4304
pISSN - 0896-8608
DOI - 10.1177/089686088500500313
Subject(s) - peritoneal dialysis , ultrafiltration (renal) , peritoneal equilibration test , tonicity , medicine , urology , renal function , endocrinology , continuous ambulatory peritoneal dialysis , chemistry , chromatography
Peritoneal ultrafiltration, creatinine clearance and glucose absorption were measured in 56 CAPD patients using a single hypertonic exchange with a four-hour dwell. The intraindividual coefficient of variation for these parameters was less than 5 % and the results obtained correlated significantly with those obtained using a six-hour dwell. Ultrafiltration capacity was independent of clearance values but glucose absorption correlated directly with clearance and inversely with ultrafiltration levels (p < 0.001). Multiple regression analysis showed a decline in four-hour clearance values with time on CAPD (p < 0.001), and an increase in glucose absorption after four hours with Frezenius hypertonic solution (p < 0.02) but no other effect of patient age, sex, body surface area, serum albumin, duration of CAPD treatment, peritonitis history or dialysate brand on these indices of peritoneal function. It is important to monitor peritoneal function in patients treated by CAPD and these results indicate that a single, timed, hypertonic exchange is a reproducible test of ultrafiltration, clearance and glucose absorption. Loss of peritoneal function is reported as a cause of failure of CAPD (1–5) although we have limited information concerning sequential changes in the peritoneal membrane with time (6–8) and no agreement over the most appropriate investigation to monitor its permeability (9–11). The International Co-operative Study measured ultrafiltration capacity using a four-hour, two-litre hypertonic exchange (9). This study examines the reliability of such a single, timed exchange to measure peritoneal clearance, glucose absorption and ultrafiltration and evaluates the influence of demographic factors on these parameters.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom