z-logo
open-access-imgOpen Access
Evaluation of the Modified Barium Swallow Study Conducted With and Without Radiologist Supervision: A Pre- and Post-Observational Study
Author(s) -
Luhe Yang,
David A. Leswick,
M. Butler,
Tasha Ellchuk
Publication year - 2021
Publication title -
canadian association of radiologists journal
Language(s) - English
Resource type - Journals
eISSN - 1488-2361
pISSN - 0846-5371
DOI - 10.1177/08465371211020630
Subject(s) - medicine , fluoroscopy , radiology , nuclear medicine , observational study , tertiary care , retrospective cohort study , surgery
Purpose: Assess quality metrics of modified barium swallow studies (MBSS) with and without a radiologist present during the procedure.Methods: Retrospective review of MBSS performed on adult inpatients at a tertiary care hospital 6-months pre- and post-institutional change from having to not having a radiologist present during the examination.Factors assessed included: fluoroscopy time; study duration; number of cine loops; number of images; efficiency of collimation (using a 5-point scoring system); time to final report; radiologist-speech language pathologist report disagreement; and recalls for inadequate studies. Statistical analysis was via Welch’s t-test and a test of proportions for continuous and count data under the normal approximation.Results: 106 and 119 MBSS were analyzed from the radiologist present and radiologist absent periods, respectively. No statistically significant differences were found for: average fluoroscopy time (116.1 s vs. 126.9 s; P = 0.161); study duration (400.4 s vs. 417.3 s; P = 0.453); number of cine loops (9.3 vs. 10.2; P = 0.075); number of images (620.5 vs. 581.1; P = 0.350); or report disagreement. There was improved performance without the radiologist present for collimation (1.92 vs. 1.43; P = 0.003) and fewer non-diagnostic images (6.5 vs. 4.5; P = 0.001). Time to final report was longer with the radiologist absent due to more reports with significant delays. There were no repeated studies because of inadequate technique in either group.Conclusion: MBSS performed by technologists without radiologist supervision is not inferior to those performed with radiologist supervision on multiple performance measures. This supports technologist operated MBSS without radiologist supervision, while acknowledging a need to further address radiologist report time delay.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom