Improved Detection Limit in Rapid Detection of Human Enterovirus 71 and Coxsackievirus A16 by a Novel Reverse Transcription–Isothermal Multiple-Self-Matching-Initiated Amplification Assay
Author(s) -
Xiong Ding,
Kai Nie,
Lei Shi,
Yong Zhang,
Li Guan,
Dan Zhang,
Shunxiang Qi,
Xuejun Ma
Publication year - 2014
Publication title -
journal of clinical microbiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.349
H-Index - 255
eISSN - 1070-633X
pISSN - 0095-1137
DOI - 10.1128/jcm.03298-13
Subject(s) - reverse transcription loop mediated isothermal amplification , loop mediated isothermal amplification , reverse transcriptase , detection limit , sybr green i , microbiology and biotechnology , real time polymerase chain reaction , virology , biology , reverse transcription polymerase chain reaction , coxsackievirus , enterovirus 71 , gene , dna , chemistry , polymerase chain reaction , virus , enterovirus , messenger rna , chromatography , genetics
Rapid detection of human enterovirus 71 (EV71) and coxsackievirus A16 (CVA16) is important in the early phase of hand-foot-and-mouth disease (HFMD). In this study, we developed and evaluated a novel reverse transcription–isothermal multiple-self-matching-initiated amplification (RT-IMSA) assay for the rapid detection of EV71 and CVA16 by use of reverse transcriptase, together with a strand displacement DNA polymerase. Real-time RT-IMSA assays using a turbidimeter and visual RT-IMSA assays to detect EV71 and CVA16 were established and completed in 1 h, and the reported corresponding real-time reverse transcription–loop-mediated isothermal amplification (RT-LAMP) assays targeting the same regions of the VP1 gene were adopted as parallel tests. Through testing VP1 RNAs transcribedin vitro , the real-time RT-IMSA assays exhibited better linearity of quantification, withR 2 values of 0.952 (for EV71) and 0.967 (for CVA16), than the real-time RT-LAMP assays, which hadR 2 values of 0.803 (for EV71) and 0.904 (for CVA16). Additionally, the detection limits of the real-time RT-IMSA assays (approximately 937 for EV71 and 67 for CVA16 copies/reaction) were higher than those of real-time RT-LAMP assays (approximately 3,266 for EV71 and 430 for CVA16 copies/reaction), and similar results were observed in the visual RT-IMSA assays. The new approaches also possess high specificities for the corresponding targets, with no cross-reactivity observed. In clinical assessment, compared to commercial reverse transcription-quantitative PCR (qRT-PCR) kits, the diagnostic sensitivities of the real-time RT-IMSA assays (96.4% for EV71 and 94.6% for CVA16) were higher than those of the real-time RT-LAMP assays (91.1% for EV71 and 90.8% for CVA16). The visual RT-IMSA assays also exhibited the same results. In conclusion, this proof-of-concept study suggests that the novel RT-IMSA assay is superior to the RT-LAMP assay in terms of detection limit and has the potential to rapidly detect EV71 and CVA16 viruses.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom