A CFD Assessment of Entrance Area Distributions in a Centrifugal Compressor Vaneless Diffuser
Author(s) -
James M. Sorokes
Publication year - 1994
Publication title -
volume 1: turbomachinery
Language(s) - English
Resource type - Conference proceedings
DOI - 10.1115/94-gt-090
Subject(s) - centrifugal compressor , impeller , diffuser (optics) , gas compressor , stall (fluid mechanics) , computational fluid dynamics , mechanics , mechanical engineering , engineering , physics , optics , light source
The paper presents the results of a CFD study that assessed the various area distributions typically found in impeller / diffuser transitions in industrial centrifugal compressor stages. Results for two transition area schedules are compared. The findings agree with recently published data and suggest that problems exist in some standard configurations that could lead to rotating stall in the downstream vaneless diffuser.