z-logo
open-access-imgOpen Access
NOx Emission From Experimental Compact Combustors
Author(s) -
H.R. Hazard
Publication year - 1972
Language(s) - English
Resource type - Conference proceedings
DOI - 10.1115/72-gt-108
Subject(s) - nox , combustor , kerosene , residence time (fluid dynamics) , combustion , nuclear engineering , materials science , environmental science , chemistry , physics , thermodynamics , engineering , organic chemistry , geotechnical engineering
NOx emission characteristics of four basic types of experimental burners firing kerosene-type fuel at rates up to 110 lb/hr were investigated experimentally. Emission levels were found to be highly dependent upon primary-zone temperature and air-fuel ratio, but independent of firing rate and residence time over a 10:1 ratio. This independence of residence time is in marked contrast with results from simple burners used in fundamental research. The burner with the lowest NOx emission level used a cooled, rich primary zone and a lean secondary zone. Although the work was aimed at automotive Rankine-cycle systems it appears applicable to other compact combustors.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom