NOx Emission From Experimental Compact Combustors
Author(s) -
H.R. Hazard
Publication year - 1972
Language(s) - English
Resource type - Conference proceedings
DOI - 10.1115/72-gt-108
Subject(s) - nox , combustor , kerosene , residence time (fluid dynamics) , combustion , nuclear engineering , materials science , environmental science , chemistry , physics , thermodynamics , engineering , organic chemistry , geotechnical engineering
NOx emission characteristics of four basic types of experimental burners firing kerosene-type fuel at rates up to 110 lb/hr were investigated experimentally. Emission levels were found to be highly dependent upon primary-zone temperature and air-fuel ratio, but independent of firing rate and residence time over a 10:1 ratio. This independence of residence time is in marked contrast with results from simple burners used in fundamental research. The burner with the lowest NOx emission level used a cooled, rich primary zone and a lean secondary zone. Although the work was aimed at automotive Rankine-cycle systems it appears applicable to other compact combustors.