z-logo
open-access-imgOpen Access
A multicentric validation study of a novel home sleep apnea test based on peripheral arterial tonometry
Author(s) -
Bart Van Pee,
Frederik Massie,
Steven Vits,
Pauline Dreesen,
Susie Klerkx,
Jagdeep Bijwadia,
Johan Verbraecken,
Jeroen Bergmann
Publication year - 2022
Publication title -
sleep
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.222
H-Index - 207
eISSN - 1550-9109
pISSN - 0161-8105
DOI - 10.1093/sleep/zsac028
Subject(s) - medicine , polysomnography , sleep apnea , concordance , obstructive sleep apnea , hypopnea , cardiology , apnea
Study Objectives This paper reports on the multicentric validation of a novel FDA-cleared home sleep apnea test based on peripheral arterial tonometry (PAT HSAT). Methods One hundred sixty-seven participants suspected of having obstructive sleep apnea (OSA) were included in a multicentric cohort. All patients underwent simultaneous polysomnography (PSG) and PAT HSAT, and all PSG data were independently double scored using both the recommended 1A rule for hypopnea, requiring a 3% desaturation or arousal (3% Rule), and the acceptable 1B rule for hypopnea, requiring a 4% desaturation (4% Rule). The double-scoring of PSG enabled a comparison of the agreement between PAT HSAT and PSG to the inter-rater agreement of PSG. Clinical endpoint parameters were selected to evaluate the device’s ability to determine the OSA severity category. Finally, a correction for near-boundary apnea–hypopnea index values was proposed to adequately handle the inter-rater variability of the PSG benchmark. Results For both the 3% and the 4% Rules, most endpoint parameters showed a close agreement with PSG. The 4-way OSA severity categorization accuracy of PAT HSAT was strong, but nevertheless lower than the inter-rater agreement of PSG (70% vs 77% for the 3% Rule and 78% vs 81% for the 4% Rule). Conclusions This paper reported on a multitude of robust endpoint parameters, in particular OSA severity categorization accuracies, while also benchmarking clinical performances against double-scored PSG. This study demonstrated strong agreement of PAT HSAT with PSG. The results of this study also suggest that different brands of PAT HSAT may have distinct clinical performance characteristics.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom