Estimation of the total rectal dose of radical external beam and intracavitary radiotherapy for uterine cervical cancer using the deformable image registration method
Author(s) -
Kazuhiko Hayashi,
Fumiaki Isohashi,
Yuichi Akino,
Nobuhide Wakai,
Seiji Mabuchi,
Осаму Сузукі,
Yuji Seo,
Yuki Ootani,
Iori Sumida,
Yasuo Yoshioka,
Tadashi Kimura,
Kazuhiko Ogawa
Publication year - 2015
Publication title -
journal of radiation research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.643
H-Index - 60
eISSN - 1349-9157
pISSN - 0449-3060
DOI - 10.1093/jrr/rru127
Subject(s) - external beam radiotherapy , cervical cancer , medicine , radiation therapy , image registration , radiology , nuclear medicine , brachytherapy , cancer , image (mathematics) , artificial intelligence , computer science
We adapted the deformable image registration (DIR) technique to accurately calculate the cumulative intracavitary brachytherapy (ICBT) and external beam radiotherapy (EBRT) rectal dose for treating uterine cervical cancer. A total of 14 patients with primary cervical cancer radically treated with ICRT and EBRT were analysed using the Velocity AI(TM) software. Computed tomography (CT) images were registered, and EBRT and ICBT dose distributions were determined. Cumulative D2cm (3), D1cm (3) and D0.1cm (3) were calculated by simple addition of fractional values or by DIR. The accuracy of DIR was evaluated by means of a virtual phantom mimicking the rectum. The dice similarity coefficient (DSC) was calculated to evaluate rectal contour concordance between CT images before and after DIR. Virtual phantom analysis revealed that the average difference between the DIR-based phantom Dmean and the simple phantom Dmean was 1.9 ± 2.5 Gy (EQD2), and the DIR method included an uncertainty of ∼8.0%. The mean DSC between reference CT and CT was significantly improved after DIR (EBRT: 0.43 vs 0.85, P < 0.005; ICBT: 0.60 vs 0.87, P < 0.005). The average simple rectal D2cm (3), D1cm (3) and D0.1cm (3) values were 77.6, 81.6 and 91.1 Gy (EQD2), respectively; the DIR-based values were 76.2, 79.5 and 87.6 Gy, respectively. The simple addition values were overestimated, on average, by 3.1, 3.7 and 5.5 Gy, respectively, relative to the DIR-based values. In conclusion, the difference between the simple rectal dose-volume histogram (DVH) parameter addition and DIR-based cumulative rectal doses increased with decreasing DVH parameters.