Subject(s) - atmospheric pressure chemical ionization , chemistry , chromatography , detection limit , mass spectrometry , chemical ionization , chemiluminescence , gas chromatography , analytical chemistry (journal) , ionization , organic chemistry , ion
A method was developed for quantitative estimation of illicit psychostimulants in blood, with an emphasis on new psychoactive substances, based on gas chromatography nitrogen chemiluminescence detection coupled with atmospheric pressure chemical ionization quadrupole time-of-flight mass spectrometry (GC-NCD-APCI-QTOFMS). Quantitative estimation relied on the NCD's N-equimolar response to nitrogen, using amphetamine, 3,4-methylenedioxymethamphetamine (MDMA) and methylenedioxypyrovalerone as external calibrators for prim-, sec- and tert- amines, respectively. After spiking with 38 stimulants at 3 concentration levels, the donor blood samples were submitted to liquid-liquid extraction at a basic pH followed by acylation with trifluoroacetic anhydride. All but 3 psychostimulants could be analyzed with a limit of quantification (LOQ) of 0.05 mg/L. At LOQ, the coefficient of variation (CV) values for between-day accuracy was 62.3-143.3% (mean, 93.5%; median, 88.5%) and precision 6.6-22.4% (mean, 15.8%; median, 16.1%). In addition, 11 post-mortem blood samples, containing 0.08-2.4 mg/L of amphetamine (n = 5), methamphetamine (n = 4) or MDMA (n = 4), were analyzed by the GC-NCD-APCI-QTOFMS method, and the results were compared with an established electron ionization GC-MS method with appropriate calibration. The agreement between the 2 methods was 62.5-117.3%. Regarding identification, the APCI source permitted detection of the intact precursor ion, or the respective acylation product, for all of the measured compounds. The GC-NCD-APCI-QTOFMS method developed here enables instant quantitative estimation of illicit psychostimulants in blood at reasonable accuracy, without the necessity of possessing the true reference standards for each analyte.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom