Magnetic Solid-Phase Extraction of Drugs and Pesticides from Human Plasma Using COOH-mMWCNTs
Author(s) -
Hee-Sung Moon,
Ji Won Park,
Jinwoo Hwang,
Heesun Chung
Publication year - 2020
Publication title -
journal of analytical toxicology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.161
H-Index - 76
eISSN - 1945-2403
pISSN - 0146-4760
DOI - 10.1093/jat/bkaa029
Subject(s) - chemistry , solid phase extraction , extraction (chemistry) , chromatography , detection limit , sorbent , magnetic nanoparticles , nuclear chemistry , nanoparticle , adsorption , organic chemistry , materials science , nanotechnology
Carbon nanotubes (CNTs) are useful for extracting chemical compounds due to their properties, such as surface area and the potential for chemical modification. Especially the formation of CNTs with carboxylic acid functional group makes them disperse in water-based samples and have strong interaction forces with cationizable analytes. Based on these features, carboxylic acid functionalized multi-walled CNTs (COOH-MWCNTs) have been used as extraction sorbents. CNT can also be gathered using an external magnet by forming complex with iron oxide (Fe3O4) magnetic nanoparticles (MNPs). In this study, COOH-MWCNTs with MNPs were subjected to magnetic solid-phase extraction (mSPE) in order to extract the targeted substances such as diphenhydramine, doxylamine, tramadol, escitalopram, zolpidem, diphenamid, paclobutrazol, hexaconazole, cyproconazole and mepronil from human plasma samples. The following five factors were optimized: (i) the ratio of COOH-MWCNTs to MNPs as a sorbent from 1:1 to 1:4; (ii) sorbent amount starting from 12.5 to 75%; (iii) sample pH tested pH 2 to pH 10 with 1 N hydrochloride and 1 N sodium hydroxide; (iv) agitating time from 0 to 4 min and (v) elution solvent. Limit of detection of 10 targeted substances in human plasma were in the range of 0.1–0.4 mg/L. The recovery of targeted substances (except diphenamid) in human plasma was 73.06–110.28% for intra-day and 83.00–107.70% for inter-day and the precision (relative standard deviation, %) in human plasma was 0.3–13.3% for intra-day and 2.9–15.6% for inter-day. The method was applied to nine authentic biological samples from overdose patients in the emergency room of Chungnam National University Hospital. The performance of mSPE was compared with the liquid–liquid extraction method using ethyl acetate. The results showed that the newly developed method in this study can be used for screening analysis in forensic and clinical toxicology.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom