Postmortem Identification and Quantitation of 2,5-Dimethoxy-4-n-propylthiophenethylamine Using GC-MSD and GC-NPD
Author(s) -
BS Corbin M. Curtis,
P. Kemp,
L. Harty,
Chulyung Choi,
Dennis Christensen
Publication year - 2003
Publication title -
journal of analytical toxicology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.161
H-Index - 76
eISSN - 1945-2403
pISSN - 0146-4760
DOI - 10.1093/jat/27.7.493
Subject(s) - chromatography , chemistry , urine , ammonium hydroxide , tetrabutylammonium hydroxide , gas chromatography–mass spectrometry , gas chromatography , extraction (chemistry) , mass spectrometry , formic acid , analyte , quantitative analysis (chemistry) , detection limit , hydrochloric acid , biochemistry , inorganic chemistry , organic chemistry
2,5-Dimethoxy-4-n-propylthiophenethylamine (2C-T-7) has structural and pharmacodynamic similarities to methylenedioxymethamphetamine (MDMA). This compound was initially identified from a routine screening procedure in postmortem urine from a 20-year-old male that died in a local emergency room after reportedly insufflating 35 mg. This report describes the development of a quantitative method for 2C-T-7. A number of method parameters were studied including internal standard selection, liquid-liquid extraction scheme, and drug stability in preserved refrigerated blood. The adopted method for blood and urine involves the addition of trimethoxyamphetamine (TMA) as internal standard, alkalinization with ammonium hydroxide, and liquid-liquid extraction with n-chlorobutane. To facilitate recovery from liver, a 1:4 aqueous homogenate was pretreated with dilute perchloric acid, centrifuged, and the supernatant was extracted as previously described. In each case, 0.1% hydrochloric acid in methanol was added during the final concentration step to prevent loss of drug caused by evaporation. Samples were analyzed by gas chromatography with nitrogen-phosphorus detection (GC-NPD) and electron ionization GC-mass spectrometry (MS) utilizing selected ion monitoring. For the GC-MS analysis, the characteristic ions monitored for 2C-T-7 were m/z 226, 255, and 183 and for TMA, m/z 182. The limits of detection and quantitation in blood were 6.0 and 15.6 ng/mL, respectively, by both GC-NPD and GC-MS. The results from the postmortem case were as follows: heart blood, 57 ng/mL; femoral blood, 100 ng/mL; urine, 1120 ng/mL; and liver, 854 ng/g.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom