z-logo
open-access-imgOpen Access
Quantitation of Alprazolam and  -Hydroxyalprazolam in Human Plasma Using Liquid Chromatography Electrospray Ionization MS-MS
Author(s) -
Dennis J. Crouch,
Douglas E. Rollins,
Dennis V. Canfield,
David M. Andrenyak,
J. E. Schulties
Publication year - 1999
Publication title -
journal of analytical toxicology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.161
H-Index - 76
eISSN - 1945-2403
pISSN - 0146-4760
DOI - 10.1093/jat/23.6.479
Subject(s) - chromatography , chemistry , high performance liquid chromatography , electrospray ionization , formic acid , metabolite , mass spectrometry , selected reaction monitoring , electrospray , tandem mass spectrometry , biochemistry
A sensitive and specific electrospray ionization high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) method has been developed for the quantitative determination of alprazolam (AL) and alpha-hydroxyalprazolam (OH-AL) in plasma. After the addition of deuterium labeled internal standards of AL and OH-AL, plasma samples were buffered to alkaline pH and extracted with toluene/methylene chloride (7:3). Dried extract residues were reconstituted in HPLC mobile phase and injected onto a reversed-phase C18 HPLC column. The analytes were eluted isocratically at a flow rate of 250 microL/min using a solvent composed of methanol and water (60:40) containing 0.1% formic acid. The analyses were performed using selected reaction monitoring. The assay was sensitive to 0.05 ng/mL for both the parent drug and metabolite and linear to 50 ng/mL. The intra-assay percent coefficients of variation (%CV) for AL at 2, 5, and 20 ng/mL were all < or = 5.6. At these concentrations, and all OH-AL intra-assay %CVs were < or = 8.4. The interassay variabilities for AL were 11.8%CV, 8.7%CV, and 8.7%CV at 2.0, 5.0, and 20.0 ng/mL, respectively. The OH-AL interassay variabilities were 9.6%CV, 9.2%CV, and 7.8%CV at the same concentrations, respectively. The assay accuracy was less than or equal to +/- 6.6% for both analytes at the three concentrations. The method was used to quantitate AL and OH-AL in plasma samples collected from 10 subjects who were administered a 1-mg oral dose of AL. The mean AL concentration peaked at 11.5 ng/mL 1 h after the dose and AL was detectable for 48 h. The mean OH-AL concentration peaked at 0.18 ng/mL 4 h after the dose and was undetectable by 36 h. Hydrolysis of the plasma samples had little effect on the detected AL concentrations but increased OH-AL concentrations substantially. Plasma/blood ratios for AL and OH-AL exceeded 1 in the study samples.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom