Rapid Method for the Determination of Thiamine and Pantothenic Acid in Infant Formula and Milk-Based Nutritional Products by Liquid Chromatography‒Tandem Mass Spectrometry
Author(s) -
Brendon D. Gill,
Sheila C. Saldo,
Iain J McGrail,
Jackie E Wood,
Harvey E. Indyk
Publication year - 2020
Publication title -
journal of aoac international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.432
H-Index - 87
eISSN - 1944-7922
pISSN - 1060-3271
DOI - 10.1093/jaoacint/qsz034
Subject(s) - pantothenic acid , thiamine , repeatability , chromatography , chemistry , liquid chromatography–mass spectrometry , certified reference materials , vitamin , mass spectrometry , biochemistry , detection limit
Background Thiamine and pantothenic acid play a critical role in numerous metabolic reactions and are typically supplemented in infant and adult nutritional formulas as thiamine chloride hydrochloride and calcium pantothenate salts. Objective A rapid compliance method for the analysis of thiamine and pantothenic acid applicable to infant formula and milk-based nutritional products is described. Method Proteins are removed by centrifugal ultrafiltration, followed by analysis by reversed-phase liquid chromatography‒tandem mass spectrometry (LC-MS/MS), with quantitation accomplished by internal standard technique. Results The method was shown to be accurate, with acceptable recovery (thiamine, 99.3–101.1%; pantothenic acid, 99.2–108.6%). A certified reference material (NIST 1849a), showed no statistical bias (α = 0.05) for thiamine (P = 0.64); although a statistically significant bias (P < 0.01) for pantothenic acid was found, the nominal bias was only 4.7% (mean = 7.1 mg/hg; certified value = 6.8 mg/hg). A comparison of results by LC-MS/MS and current methods showed negligible bias (mean bias: thiamine, 0.01 mg/hg; pantothenic acid, 0.17 mg/hg) and no statistical significance (α = 0.05; thiamine, P = 0.399; pantothenic acid, P = 0.058). Acceptable precision was demonstrated with a repeatability of 7.2% repeatability relative standard deviation (RSDr) (HorRat: 0.6) and an intermediate precision of 7.0% RSD for thiamine, and a repeatability of 5.7% RSDr (HorRat: 0.5) and an intermediate precision of 6.1% RSD for pantothenic acid. Conclusions This rapid method is intended for use in high-throughput laboratories as part of routine product compliance release testing of thiamine and pantothenic acid in manufactured infant and milk-based nutritional products.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom