Direct intracardiac placement of an automatic implantable cardioverter defibrillator coil lead in a small child
Author(s) -
Michal J. Kantoch,
Ivan M. Rebeyka,
Lois A. Houlden,
John D. Dyck
Publication year - 2007
Publication title -
ep europace
Language(s) - English
Resource type - Journals
eISSN - 1532-2092
pISSN - 1099-5129
DOI - 10.1093/europace/eum036
Subject(s) - medicine , intracardiac injection , implantable cardioverter defibrillator , cardiology , ventricular outflow tract , lead (geology) , surgery , geomorphology , geology
A 3.5-year-old child with hypertrophic obstructive cardiomyopathy and recurrent syncope underwent surgical left-ventricular outflow tract myectomy and implantation of a single-chamber automatic cardioverter defibrillator. A single-coil active fixation lead was introduced via a purse-string suture in the right atrial appendage and the lead tip positioned and fixed in the right-ventricular apex under direct visualization via a small right atriotomy incision. Described configuration may be considered in small children undergoing intracardiac surgery at the time of defibrillator implantation.