HPLC Determination of Thiopurine Nucleosides and Nucleotides in Vivo in Lymphoblasts following Mercaptopurine Therapy
Author(s) -
Thierry Dervieux,
Ya-Qin Chu,
Yi Su,
ChingHon Pui,
William E. Evans,
Mary V. Relling
Publication year - 2002
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1093/clinchem/48.1.61
Subject(s) - thiopurine methyltransferase , mercaptopurine , chemistry , chromatography , lymphoblast , nucleotide , high performance liquid chromatography , analyte , biochemistry , pharmacology , azathioprine , biology , cell culture , medicine , disease , gene , pathology , genetics
BACKGROUNDMercaptopurine is a prodrug requiring intracellular activation to thiopurine nucleotides to exert antileukemic effect. We developed a reversed-phase liquid chromatographic assay for the quantification of mercaptopurine, thioguanine, and methylmercaptopurine nucleoside and nucleotide concentrations in the target tissue, the leukemic lymphoblast.METHODSLeukemic blasts were isolated from peripheral blood and bone marrow by a standard Ficoll-hypaque procedure. Proteins were removed by ultrafiltration in the presence of dithiothreitol. Thiopurine ribonucleotides were converted into their respective ribonucleosides by treatment of ultrafiltrate with acid phosphatase. Thiopurine nucleosides and bases were measured by direct injection of ultrafiltrate into the chromatographic system. Thiopurine nucleotide concentrations were calculated by subtracting the thiopurine nucleoside concentrations measured after treatment with acid phosphatase from those measured after direct injection of ultrafiltrate in the chromatographic system. Analytes were separated on a C18 Supelco column with ammonium phosphate-methanol eluent coupled with ultraviolet detection.RESULTSCVs for intra- and interday precision were 1.1-14% (median, 4.9%), and recovery of added analyte was 89-126% (median, 105%) at low and high concentrations of analytes, except for mercaptopurine riboside. The median signal for each of the five metabolites in lymphoblast samples was 98% (range, 80-106%) of that in water. Detection limits for thiopurine bases and nucleosides ranged from 0.5 to 4.5 pmol/5 x 10(6) cells.CONCLUSIONSThis method is suitable for measurement of thiopurine metabolite concentrations in lymphoblasts in children with acute lymphoblastic leukemia following a single dose of intravenous mercaptopurine.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom