Analytical and Clinical Evaluation of Two Homogeneous Assays for LDL-Cholesterol in Hyperlipidemic Patients
Author(s) -
Margarita Esteban-Salán,
Amada Guimón-Bardesi,
Jesús María de la Viuda-Unzueta,
María Nerea Azcarate-Ania,
Pilar Pascual-Usandizaga,
Eduardo Amoroto-Del-Río
Publication year - 2000
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1093/clinchem/46.8.1121
Subject(s) - triglyceride , ldl cholesterol , homogeneous , medicine , roche diagnostics , chemistry , cholesterol , hyperlipidemia , endocrinology , chromatography , mathematics , diabetes mellitus , combinatorics
BACKGROUNDLDL-cholesterol (LDL-C) concentrations are the primary basis for treatment guidelines established for hyperlipidemic patients. LDL-C concentrations are commonly monitored by means of the Friedewald formula, which provides a relative estimation of LDL-C concentration when the triglyceride concentration is <2000 mg/L and there are no abnormal lipids. The Friedewald formula has several limitations and may not meet the current total error requirement of <12% in LDL-C measurements.METHODSWe evaluated the analytical and clinical performance of two direct methods (Roche and Wako) by analyzing 313 fresh serum samples obtained from dyslipidemic patients in a lipid clinic and comparing them with modified beta-quantification.RESULTSBoth homogeneous assays displayed excellent precision (CV <2%). The Roche method showed a mean total error of 7.72%, and the Wako method showed a mean total error of 4.46% over a wide range of LDL-C concentrations. The Roche method correlated highly with the modified beta-quantification assay (r = 0.929; y = 1.052x - 168 mg/L; n = 166) and showed a bias of -4. 5% as a result of the assigned standard value. The Wako method also correlated highly with beta-quantification (r = 0.966; y = 0.9125x + 104.8 mg/L; n = 145) without significant bias. The Roche method correctly classified 97% of patients with triglycerides <2000 mg/L, 75% of patients with type IIb hyperlipemia (HPL), and 84% of patients with type IV HPL based on the cutpoints of 1300 and 1600 mg/L, compared with 98%, 78.4%, and 89%, respectively, for the Wako method. In dysbetalipoproteinemic patients, both methods have a 30% mean positive bias compared with beta-quantification.CONCLUSIONSBoth direct methods can be a useful alternative when ultracentrifugation is not available for the diagnosis and control of lipid-lowering medication for patients with mixed HPL, but not for patients with type III hyperlipidemia.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom