Comparison of the Axis %CDT TIA and the CDTect method as laboratory tests of alcohol abuse
Author(s) -
Katja Viitala,
Kaija Lähdesmäki,
Onni Niemelä
Publication year - 1998
Publication title -
clinical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.705
H-Index - 218
eISSN - 1530-8561
pISSN - 0009-9147
DOI - 10.1093/clinchem/44.6.1209
Subject(s) - alcohol , medicine , alcohol abuse , alcoholic intoxication , medical emergency , psychology , suicide prevention , poison control , psychiatry , chemistry , organic chemistry
Carbohydrate-deficient transferrin (CDT) has been suggested as a specific marker of alcohol abuse. We designed this study to compare the conventional CDTect method (Pharmacia & Upjohn) and the new semiautomated Axis %CDT turbidimetric immunoassay (%CDT TIA) for their diagnostic performance to identify problem drinking. The sensitivities of the %CDT TIA and CDTect for correctly classifying heavy drinkers (n = 90) were 29% and 59% with the thresholds currently recommended by the manufacturers, respectively. In the control group (n = 114), which included hospitalized patients with abnormal serum transferrin concentrations, the CDTect assay gave 21 false-positive values (18%), whereas the %CDT TIA showed 100% specificity. With the cutoff limits based on the present healthy control group (mean + 2 SD), the sensitivities of the %CDT TIA and CDTect were 61% and 86%, respectively. For men, the ROC plot area of the CDTect results in comparisons of alcohol abusers and healthy controls was significantly (P < 0.05) higher than that of the %CDT TIA results, whereas for women, there was no significant difference in this respect. The slope and intercept (with 95% confidence intervals) for linear regression between CDTect and %CDT TIA were 0.13 (0.12-0.15) and 1.16 (0.73-1.59), respectively (S(y/x) = 1.51, r = 0.744). CDTect results correlated positively with serum transferrin (r = 0.224, P < 0.001), whereas the %CDT TIA results showed a slight inverse correlation with serum transferrin (r = -0.132, P = 0.07). The data suggest that CDTect is more sensitive than %CDT TIA in detecting drinking problems. However, the %CDT TIA method yields more specificity when analyzing samples from patients with high serum transferrin concentrations.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom