Ultrasound induced improvement in optical coherence tomography (OCT) resolution
Author(s) -
John O. Schenk,
Mark E. Brezinski
Publication year - 2002
Publication title -
proceedings of the national academy of sciences
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 5.011
H-Index - 771
eISSN - 1091-6490
pISSN - 0027-8424
DOI - 10.1073/pnas.142155899
Subject(s) - optical coherence tomography , optics , ultrasound , transducer , photoacoustic doppler effect , materials science , ultrasonic sensor , scattering , bandwidth (computing) , doppler effect , physics , laser , acoustics , computer science , telecommunications , astronomy
Optical coherence tomography (OCT) is a rapidly emerging technology for high-resolution biomedical imaging. The axial resolution of this technology is determined by the bandwidth of the source. Commercial sources generally provide resolutions of 10-20 microm whereas laboratory-based solid state lasers have resolutions of approximately 4 microm. The resolution in tissue depends almost exclusively on detecting single scattered events. However, the phenomenon known as multiple scattering results in a deterioration of resolution as a function of depth. In this study, OCT was combined with ultrasound in an attempt to reduce the effect of multiple scattering. The theory is that, with parallel ultrasound and OCT beams, multiply scattered light with a momentum component significantly perpendicular to the OCT beam will be reduced because the light is Doppler shifted outside the bandpass filter of the OCT detection electronics. A 7.5-MHz ultrasound transducer was used to introduce the photon/phonon interaction. A reflecting metal plate was placed within biological tissue, and the point spread function (PSF) was assessed off the reflector. The PSF was determined in the presence of no ultrasound, pulsed ultrasound, and continuous-wave (CW) ultrasound. CW ultrasound resulted in a 17% improvement (P < 0.001) in resolution and pulsed ultrasound resulted in 8% (P < 0.01). Image noise reduction could also be noted. Combining OCT with a parallel ultrasound beam results in an improvement in resolution through a reduced effect of multiple scattering due to photon/phonon interaction. With higher frequencies, better control of the acoustical beam, and tests in media with higher rates of multiple scattering, improved results are anticipated.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom