z-logo
open-access-imgOpen Access
Single shot zonal oblique multislice SE-EPI diffusion-weighted imaging with low to ultra-high b-values for the differentiation of benign and malignant vertebral spinal fractures
Author(s) -
Elisabeth Sartoretti,
Sabine SartorettiSchefer,
Luuk van Smoorenburg,
Barbara Eichenberger,
Árpád Schwenk,
David Czell,
Alex Alfieri,
Andreas Gutzeit,
Manoj Mannil,
Christoph A. Binkert,
Michael Wyss,
Thomas Sartoretti
Publication year - 2021
Publication title -
european journal of radiology open
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.49
H-Index - 15
ISSN - 2352-0477
DOI - 10.1016/j.ejro.2021.100377
Subject(s) - medicine , nuclear medicine , multislice , echo planar imaging , diffusion mri , radiology , magnetic resonance imaging
Purpose To investigate the diagnostic yield of low to ultra-high b-values for the differentiation of benign from malignant vertebral fractures using a state-of-the-art single-shot zonal-oblique-multislice spin-echo echo-planar diffusion-weighted imaging sequence (SShot ZOOM SE-EPI DWI). Materials and Methods 66 patients (34 malignant, 32 benign) were examined on 1.5 T MR scanners. ADC maps were generated from b-values of 0,400; 0,1000 and 0,2000s/mm 2 . ROIs were placed into the fracture of interest on ADC maps and trace images and into adjacent normal vertebral bodies on trace images. The ADC of fractures and the Signal-Intensity-Ratio (SIR) of fractures relative to normal vertebral bodies on trace images were considered quantitative metrics. The appearance of the fracture of interest was graded qualitatively as iso-, hypo-, or hyperintense relative to normal vertebrae. Results ADC achieved an area under the curve (AUC) of 0.785/0.698/0.592 for b = 0,400/0,1000/0,2000s/mm 2 ADC maps respectively. SIR achieved an AUC of 0.841/0.919/0.917 for b = 400/1000/2000s/mm 2 trace images respectively. In qualitative analyses, only b = 2000s/mm 2 trace images were diagnostically valuable (sensitivity:1, specificity:0.794). Machine learning models incorporating all qualitative and quantitative metrics achieved an AUC of 0.95/0.98/0.98 for b-values of 400/1000/2000s/mm 2 respectively. The model incorporating only qualitative metrics from b = 2000s/mm 2 achieved an AUC of 0.97. Conclusion By using quantitative and qualitative metrics from SShot ZOOM SE-EPI DWI, benign and malignant vertebral fractures can be differentiated with high diagnostic accuracy. Importantly qualitative analysis of ultra-high b-value images may suffice for differentiation as well.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom