z-logo
open-access-imgOpen Access
Inter‐ and intrarater reliability of four single‐legged hop tests and isokinetic muscle torque measurements in children
Author(s) -
Johnsen Marianne Bakke,
Eitzen Ingrid,
Moksnes Håvard,
Risberg May Arna
Publication year - 2015
Publication title -
knee surgery, sports traumatology, arthroscopy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.806
H-Index - 125
eISSN - 1433-7347
pISSN - 0942-2056
DOI - 10.1007/s00167-013-2771-x
Subject(s) - intraclass correlation , hop (telecommunications) , concentric , intra rater reliability , torque , reliability (semiconductor) , standard error , orthodontics , knee flexion , physical medicine and rehabilitation , physical therapy , mathematics , medicine , computer science , reproducibility , rating scale , statistics , physics , power (physics) , thermodynamics , geometry , quantum mechanics , computer network
Purpose Single‐legged hop tests and isokinetic muscle torque are common outcome measures in the evaluation of knee function. The reliability of the single‐legged hop tests in children has not been documented. The aim was to examine inter‐ and intrarater reliability of four single‐legged hop tests and isokinetic muscle torque measurements in children. Methods Twenty‐eight sports‐active children (12.4 ± 0.3 years old) were tested three times in two test sessions separated by 1 week. They performed four single‐legged hop tests and concentric isokinetic torque measurements during knee extension and flexion. Inter‐ and intrarater reliability were calculated using the intraclass correlation coefficient (ICC 2,1). Relative terms of the standard error of measurement (SEM %) and smallest real difference (SRD %) were emphasized to allow comparison between the different variables. Results Twenty‐six children were included for statistical analysis. ICCs for inter‐ and intrarater reliability were moderate to high for the hop tests (0.62–0.91) and isokinetic measurements (0.76–0.87). SEMs % were low for the hop tests (3.9–7.4 %) and the isokinetic measurements (5.2–8.9 %). SRDs % were 20.5 % or less for the hop tests, 15.7 % or less for knee extension, and 24.6 % or less for knee flexion. Conclusion The single‐legged hop tests and isokinetic muscle torque measurements demonstrated moderate‐to‐high reliability with low measurement error in sports‐active children. A change above 20.5 % for the single‐legged hop tests, 15.7 % for knee extension, and 24.6 % for knee flexion is necessary to represent a real change in knee function. Level of evidence III.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom