z-logo
open-access-imgOpen Access
Erfolgreiche Behandlung einer subglottischen Trachealstenose mittels Mukosa-Radialisfaszien-Lappen
Author(s) -
Magis Mandapathil,
Thomas K. Hoffmann,
Lutz Freitag,
D. Nageshwar Reddy,
Stephan Lang,
Pierre Delaere
Publication year - 2012
Publication title -
hno
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.438
H-Index - 36
eISSN - 1433-0458
pISSN - 0017-6192
DOI - 10.1007/s00106-012-2624-9
Subject(s) - medicine , head and neck surgery , gynecology , otorhinolaryngology , surgery
Short-segment tracheal stenosis is often treated by segmental resection and end-to-end anastomosis. Longer-segment stenosis can sometimes be treated using dilation, laser therapy, bronchoscopic stent insertion and segmental resection and reconstruction. Long-segment restenosis with a buildup of scar tissue due to successful resection surgery in the past represents a particular therapeutic challenge and a sufficiently vascularized transplant may be the only option. We describe the case of a 37-year-old patient who underwent a tracheal reconstruction using a mucosa-lined radial forearm flap. Subsequent to a traumatic laryngotracheal fracture, long-term ventilation and multiple surgical interventions, the patient had developed a functionally relevant subglottic stenosis (5.5 cm). Following longitudinal anterior resection of the trachea 1 cm above and below the stenosis, a Dumon® stent was inserted. Simultaneously, a radial forearm fascia flap was harvested, as were two full-thickness buccal mucosa grafts, which were sutured onto the subcutaneous tissue and fascia of the forearm flap. Beginning caudally, the mucosa-lined flap was then sutured, air-tight, into the anterior tracheal defect with the mucosa facing the lumen. Finally, end-to-end anastomosis connected the blood vessels of the radial forearm flap to the recipient blood vessels in the neck. The patient was successfully extubated after 24 h and discharged after 5 days. A postoperative CT scan revealed optimal placement of the stent and the patient's speech and breathing were sufficiently re-established. The stent was removed bronchoscopically 6 weeks after surgery. Examinations during the 6-month follow-up period showed that the diameter of the reconstructed airway was retained and the patient remained symptom-free.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom