Перераспределение токов и тепловых потерь в реверсивно-включаемом динисторе при наличии поперечного перепада температуры
Author(s) -
А.В. Горбатюк,
Б.В. Иванов
Publication year - 2019
Publication title -
pisʹma v žurnal tehničeskoj fiziki
Language(s) - English
Resource type - Journals
eISSN - 1726-7471
pISSN - 0320-0116
DOI - 10.21883/pjtf.2019.01.47160.17547
Subject(s) - heat sink , repetition (rhetorical device) , power (physics) , voltage , transverse plane , mechanics , temperature gradient , electrical engineering , materials science , physics , engineering , thermodynamics , meteorology , structural engineering , philosophy , linguistics
The effects of a transverse temperature gradient in reversively switched-on dynistors have been studied. Taking into account these effects is important for high-voltage frequency dynistor assemblies because of the problems of a distributed cooling of the devices. A simulation description is given for the spatial dynamics of charges and heat in dynistor chips in switching of repeated current pulses. An estimation method is suggested for calculating the maximum repetition frequency coordinated with the heatsink heatsink cooling power.