In Vivo Validation of the M-COVX® Metabolic Monitor in Patients under Anaesthesia
Author(s) -
Christopher Stuart-Andrews,
Philip J. Peyton,
Gavin J. B. Robinson,
David Terry,
Brendan O’Connor,
C. Van der Herten,
Brian Lithgow
Publication year - 2007
Publication title -
anaesthesia and intensive care
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.494
H-Index - 62
eISSN - 1448-0271
pISSN - 0310-057X
DOI - 10.1177/0310057x0703500314
Subject(s) - medicine , cardiopulmonary bypass , anesthesia , respiratory monitoring , perioperative , oxygen , biomedical engineering , surgery , respiratory system , chemistry , organic chemistry
A practical method of breath-by-breath monitoring of metabolic gas exchange has been developed by GE Healthcare/Datex Ohmeda and incorporated into existing anaesthetic and critical care monitoring systems (M-COVX®). This device relates flow measurements made at the mouth by pneumotachograph to measurements of inspired and expired gas composition by matching the two waveforms thereby allowing continuous, breath-by-breath monitoring of an intubated patient's oxygen uptake and carbon dioxide production. Given that there is a paucity of data comparing this new device against methods more widely used clinically, we tested the device on 11 patients undergoing cardiopulmonary bypass surgery. Using a standard anaesthetic machine (Datex Ohmeda Excel 210 SE) with a semi-closed circle absorber system, oxygen uptake was measured at the mouth continuously throughout the operation at approximately six-second intervals. The data were compared against the reverse Fick method and against standard indirect calorimetry using the Haldane transformation. When compared to the calculated reverse Fick oxygen uptake, a mean difference of +16.5% was found pre-bypass and +9.9% post-bypass, consistent with uptake of oxygen by lung tissue, which is not taken into account by the reverse Fick method. Measurements made comparing the M-COVX metabolic monitor against standard Haldane showed a mean difference of +5.1% pre-bypass and –2.1% post-bypass. Given the ease with which this device can be incorporated into existing anaesthetic monitoring systems and its accuracy in measuring oxygen uptake, the M-COVX module is an attractive addition to existing perioperative monitoring.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom